34
2
INSTALLATION PROCEDURE
302.061
The bar end signal K1 is sent to the lathe as soon as the bar feeder detects
the end of the bar.
0-
At the FEEDING signal the K2 relay is disabled when the bar feeding
is performed; it is enabled when the bar reaches the bar stop (bar stop
encoder).
1-
The K2 relay is enabled when the bar feeding is performed and disabled
when the bar reaches the bar stop (bar stop encoder).
This is the thrust used during the FEEDING phase.
32
Fase
machining
:>0
no.32 K1 immediate e
xit
33
Phase
machining
:>0
no.33 K2 inversion
34
Phase
machining
:>300
no.34 Feeding torque
(200)

Table of Contents