System Parameters menu, and then select Setup Port8. Press [Cancel] to return to the .
Select the port to setup, and select the correct baud rate, data bits, stop bits, and
parity.
9. After all the settings are updated, the terminal will update the system parameter setting,
when you exit the Extended Menu, the terminal will reset.
12.3 Default Setup Configuration
Configuration Default Value
IBMEFT/NCR protocol selection IBMEFT
Download Port Number Com1
Download Port Type RS232
RS232 baud rate 19200
RS232 data bits 8
RS232 parity No parity
RS232 stop bits 1
12.4 Error: Bad Prog.
The flash memory in the terminal may not match the flash memory requirement of EFTL
file. Contact your account manager to arrange to have the terminal sent in for repair.
12.5 Device already loaded with program x and
parameter y
This error message displays on the computer or cash register if the Ingenico 6780 has
already been upgraded.
12.6 CRC Error
The CRC Error message, followed by multiple characters in a string, displays on the
Ingenico 6780 to indicate that the Security Module has been compromised. Notate error to
report with issue. Notify your Ingenico project m anager immediately and request RMA
number authorization to return unit to an authorized repair facility for recovery.
108 Chapter 12 Download Errors
Section 12.3 Default Setup Configuration