Programming manual
Programming partitions 37
AUTOMATIC
ARMING/
DISARMING
The association of a timer with a partition will allow it to arm or disarm automatically at the
ON/OFF times set on the timer.
This function must be enabled or disabled for each single partition.
Type-in Code
(User)
, Activations, Auto-arm
This section lists the partitions on which to activate or not automatic arm/disarm operations
by means of the and buttons.
Forced auto-arm operations may occur, generated by events active at the time of the auto-
arm operation.