Programming manual
Programming the control panel 33
4-5
Compliance 50131 grade 3
The Prime/STUDIO software provides a section for a configuration of the control panel that
complies with grade 3 of 50131 regulations.
However, total respect of the said regulations is obtained by appropriately setting also the
other options related to grade 2. For this purpose refer to Chapter 19 Compliance with rules
in force..
Thermostat on keypad Yes Yes Nexus loss Yes Yes
Activate scenario Yes No Video detector loss Yes Yes
Emergency button Yes No Jamming Yes Yes
Panic Yes No Low battery wireless zone Yes Yes
Open-panel tamper Yes Yes Wireless zone loss Yes Yes
Control panel Tamper Yes Yes Valid Installer code Yes No
Zone fuse fault Yes Yes Invalid code Yes No
I-BUS fuse fault Yes Yes False key Yes No
Battery fault Yes Yes GSM trouble Yes No
Mains failure Yes Yes Input undergoing programming Yes Yes
Expansion tamper Yes Yes Output fault Yes No
Keypad Tamper Yes Yes Low credit Yes No
Table 4-5: Preset events for the Cloud
Event
Communication to Cloud in case
of
Event
Communication to Cloud in case
of
Activation Reset Activation Reset
Table 4-6: Parameters for compliance
Parameter Software section Installer menu section
This section allows you to select which faults or events, other than zones in
alarm status, will be signalled as system security-risk conditions when the
partition arms.
Regulatory
compatibility
Forced arming
faults
Other parameters,
FaultForNotReady
Overload AUX1
An overcurrent detected on “AUX1”.
Zone fuse fault
Overload I-BUS
An overcurrent was detected on the BUS power
supply channel.
IBUS fuse fault
Low battery
The backup battery is low
Low battery
Mains failure
The primary power supply 230V~ fails
Mains failure
Telephone line down
The land line is not working
Tel. line down
Jamming
Wireless interference detected
Jamming
Low battery wireless
The battery of a least one wireless detector must be
replaced
Low battery WLS
Wireless zone loss
Loss of at least one wireless detector has been
signalled (supervisory time expired)
WLS zone loss
Loss or tamper ongo-
ing
This warning groups together the following events:
Control panel open
Dislodged panel
Expansion tamper
Keypad Tamper
Reader Tamper
Sounder/flasher tamper
Nexus tamper
Home-automation module tamper
Expansion Loss
Keypad Loss
•Reader Loss
Sound.flash.Loss
•Nexus loss
Home-automation module loss
LossTamp.ongoing
GSM BUS fault
Nexus device fault
Nexus fault
Faults on zones
Violation has occurred on one or more zones with
the “Fault zone” option enabled.
Faults on zones
Sounder faults
Fault present on one of the sounder/flashers
Sounder faults