64 Programming events
Anti-intrusion control panels
Chapter
12
Programming events
The programming of events includes the programming of the actions the control panel must
carry out when events occur. The control panel recognizes all of the events described in this
paragraph and, in accordance with programming, is capable of generating pre-programmed
actions for each event, both when the event occurs and when it restores/ends.
The actions are:
• activation of outputs
• activation/deactivation of outputs
• event notification via phone call
• send SMS text messages
• event storage
• management of voice messages
• management of the option of each event
• activation of event related shortcuts
• Roll up/Roll down of roller shutters
Telephone notifications (calls) are queued and sent out in chronological order. However, some
events may need to be notified immediately (for example, use of a code under duress),
therefore, such events can be given priority by selecting the “Priority” option.
Event notification via e-mail requires the use of a PrimeLAN board (refer to Chapter 13
Programming the PrimeLAN board).
Event notification via predefined SMS messages requires the use of a Nexus (refer to
paragraph 3-5-3 SMS message texts).
Note
If a list of phone calls is programmed for the notification of an event as well as SMS messages, the SMS
messages will be sent before the phone calls.
The following table shows the events the control panel recognizes (described in the Appendix
E, Event type), the number of events for each type, the activation and restoral modes of each
event and if the event is a pulse type event.
Via software Click on the Events button on the menu on the left to access the various sections on the
right:
• Events list, this section is where all the available events and their parameters are listed.
The upper programming field “Event type” filters the visualization of events, in accordance
with the type.
Selecting one of these options allows you to configure the parameters of the single event
by clicking on the button.
• Event maintenance, this section groups together all the fast programming functions of
the events.
• Configure other outputs, this section allows you to configure the set of outputs
selectable for each single event in the Other outputs section.
Via keypad
Type-in Code
(Installer PIN),
PROGRAMMING Events
This section allows you to program the various options of each selected event.
1. Using the and buttons select the event type and press OK.
2. Using the and buttons select the single event from the previously selected
type and press OK.
3. Select:
- Activation, to program the actions to be carried out when the event occurs.
- Restoral, to program the actions to be carried out when the event ends.
4. Set the parameters relating to the event activation or restoral actions.