Interroll 24-V/48-V Roller Conveyor
RM 8310/8310 DF, RM 8320/8320 DF, RM 8330/8330 DF
Troubleshooting
Version 1.5 (07/2020) en
Translation of original operating instructions
83
Fault Cause Remedy
RollerDrive operation
interrupted
RollerDrive cable damaged Check cable for damage
and replace RollerDrive if
necessary
Unusual noise coming from
the RollerDrive
Motor or gear box is damaged Replace the RollerDrive
Zone starts up intermittently
(10-second cycle)
Supply voltage outside
tolerances
Set voltage at power supply
(24 V to 26 V or 48V to
50V)