Interroll 24-V/48-V Roller Conveyor
RM 8310/8310 DF, RM 8320/8320 DF, RM 8330/8330 DF
Troubleshooting
Version 1.5 (07/2020) en
Translation of original operating instructions
83
Fault Cause Remedy
RollerDrive operation
interrupted
RollerDrive cable damaged • Check cable for damage
and replace RollerDrive if
necessary
Unusual noise coming from
the RollerDrive
Motor or gear box is damaged • Replace the RollerDrive
Zone starts up intermittently
(10-second cycle)
Supply voltage outside
tolerances
• Set voltage at power supply
(24 V to 26 V or 48V to
50V)