81
Maintenance intervals
If maintenance is not performed according to schedule, it may lead to damages and failures.
If maintenance intervals are not followed, the warranty will be void.
All bearings of the module feature a life-time lubrication and are maintenance-free within
the operating parameters.
Maintenance and inspection list
Component Interval Tasks/to check Work to be performed Performed by
Complete module Weekly General visual
and acoustic
remote check
Complete module Annually Check screw
connections
Tighten to applicable
standard as required
RollerDrive Every 6 months Check
temperature*
Replace as required
RollerDrive Every 6 months Check for noise Replace as required
RollerDrive Every 6 months Check for
damage
Replace as required
RollerDrive Annually Ensure that shaft
is secured
correctly in the
side profile
Rollers/drive belt Every 6 months Check running
behavior and
tension of drive
belts
Replace as required
Rollers/drive belt Every 6 months Check for wear/
damage
Replace as required
Rollers/drive belt Every 6 months Check for
cleanliness
Clean as required
* For permissible temperatures, see the operating manual of the motor.