Goodrive200 inverters Basic operation instruction
137
Function
code
Name Detailed instruction of parameters
Default
value
P00.15
Motor parameter
autotuning
0:No operation
1:Rotation autotuning
2:Static autotuning 1
3: Static autotuning 2
0
P00.17 Inverter type
0:G
1:P
0
P02.01 Rated power of AM 1
0.1~3000.0kW
Depend
on model
P02.02 Rated frequency of AM 1
0.01Hz~P00.03(the Max. frequency)
50.00
Hz
P02.03 Rated speed of AM 1
1~36000rpm
Depend
on model
P02.04 Rated voltage of AM 1
0~1200V
Depend
on model
P02.05 Rated current of AM 1
0.8~6000.0A
Depend
on model
P05.01~P0
5.09
Multi-function digital input
terminals
(S1~S8,HDI) function
selection
36:Shift the command to the keypad
37:Shift the command to the terminals
38:Shift the command to the
communication
P07.01 Parameter copy
The function code determines the mode
of parameters copy.
0:No operation
1:Upload the local function parameter to
the keypad
2:Download the keypad function
parameter to local address(including the
motor parameters)
3:Download the keypad function
parameter to local address (excluding the
motor parameter of P02 group)
0