Goodrive200 inverters Basic operation instruction
192
7.16 Traverse running
Traverse is applied in some industries such as textile, chemical fiber and cases where traverse and
convolution is required. The working flowchart is as below:
Function
code
Name Detailed instruction of parameters
Default
value
P00.03 Max. output frequency
P00.06 A frequency command
0:Keypad data setting
1:Analog AI1 setting
2:Analog AI2 setting
3:Analog AI3 setting
4:High-speed pulse HDI setting
5:Simple PLC program setting
6:Multi-step speed running setting
7:PID control setting
8:MODBUS communication setting
9 ~11:Reserved
0
P00.11 ACC time 1 0.0~3600.0s
Depend
on model
P00.12 DEC time 1 0.0~3600.0s
Depend
on model