7.16 Traverse running
Traverse is applied in some industries such as textile, chemical fiber and cases where traverse and
convolution is required. The working flowchart is as below:
Function
code
Name Detailed instruction of parameters
Default
value
P00.03 Max. output frequency
P00.03~400.00Hz 50.00Hz
P00.06 A frequency command
0:Keypad data setting
1:Analog AI1 setting
2:Analog AI2 setting
3:Analog AI3 setting
4:High-speed pulse HDI setting
5:Simple PLC program setting
6:Multi-step speed running setting
7:PID control setting
8:MODBUS communication setting
9 ~11:Reserved
0
P00.11 ACC time 1 0.0~3600.0s
Depend
on model
P00.12 DEC time 1 0.0~3600.0s
Depend
on model