Goodrive200 inverters Keypad operation procedure
42
cannot be modified. The possible reasons could be:
1) This function code is not modifiable parameter, such as actual detected parameter,
operation records and so on;
2) This function code is not modifiable in running state, but modifiable in stop state.
Example: Set function code P00.01 from 0 to 1.
Fig 5-3 Sketch map of modifying parameters
5.4.2 How to set the password of the inverter
Goodrive200 series inverters provide password protection function to users. Set P7.00 to
gain the password and the password protection becomes valid instantly after quitting from
the function code editing state. Press PRG/ESC again to the function code editing state,
“0.0.0.0.0” will be displayed. Unless using the correct password, the operators cannot enter
it.
Set P7.00 to 0 to cancel password protection function.
The password protection becomes effective instantly after retreating form the function code
editing state. Press PRG/ESC again to the function code editing state, “0.0.0.0.0” will be
displayed. Unless using the correct password, the operators cannot enter it.
Fig 5-4 Sketch map of password setting
5.4.3 How to watch the inverter state through function codes
Goodrive200 series inverters provide group P17 as the state inspection group. Users can
enter into P17 directly to watch the state.