Goodrive300-LIFT series inverter Function parameters
-38-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P01.03
Retention time of
the starting
frequency
Frequency (f)
f
max
t1
Time (t)
f1 is set through P01.01.
t1 is set through P01.02.
f1
Set a proper starting frequency to increase the
torque of the inverter during starting. During the
retention time of the starting frequency, the
output frequency of the inverter is the starting
frequency. And then, the inverter will run from
the starting frequency to the set frequency. If the
set frequency is lower than the starting
frequency, the inverter will stop running and
keep in the stand-by state. The starting
frequency is not limited in the lower limit
frequency.
Setting range: 0.050.0s
0.0s
P01.04
Pre-start braking
current
The inverter will carry out DC braking at the
braking current set before starting and it will
speed up after the DC braking time. If the DC
braking time is set to 0, the DC braking is invalid.
Stronger braking current indicates bigger
braking power. The DC braking current before
starting means the percentage of the rated
current of the inverter.
Setting range of P01.04: 0.0100.0%
Setting range of P01.05: 0.030.0s
0.0%
P01.05
Braking time
before starting
0.0s