EasyManuals Logo

INVT GD300L Series User Manual

INVT GD300L Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
Goodrive300-LIFT series inverter Function parameters
-39-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P01.06
ACC/DEC
selection
Changing mode of the frequency during start-up
and running.
0: Linear type
The output frequency increases or decreases
linearly.
f
max
Output frequency (f)
t1 t2
Time (t)
1: S curve, indicating the output frequency
increases or decreases according to the S
curve.
Generally, S curve is used in scenarios such as
lifts and conveyers which require smooth startup
and stop.
Output frequency (f)
Time (t)
f
max
t1 t2
0
P01.07
Stop mode
0: Decelerate to stop. After the stop command
becomes valid, the inverter decelerates to
decrease the output frequency during the set
time. When the frequency decreases to P01.15,
the inverter stops.
1: Coast to stop: after the stop command
becomes valid, the inverter ceases the output
immediately. And the load coasts to stop at the
mechanical inertia.
0
P01.08
Start frequency
in stop braking
Starting frequency of stop braking: The inverter
will carry on stop DC braking when the
frequency is arrived during decelerating to stop.
Demagnetizing time: Before the stop DC
0.00Hz
P01.09
Demagnetizing
time
0.00s
P01.10
Stop DC braking
current
0.0%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT GD300L Series and is the answer not in the manual?

INVT GD300L Series Specifications

General IconGeneral
BrandINVT
ModelGD300L Series
CategoryInverter
LanguageEnglish

Related product manuals