Loading...
Goodrive30 Series VFD Function parameter list
-49-
Function
code
Name
Description
Default
Modify
count:
1. If the nameplate
designates the
counter-emf
constant Ke, then:
E=(Ke×n
N
×2
π
)/60
2. If the nameplate
designates the
counter-emf
constant
E’(V/1000r/min),
then:
E=E’×n
N
/1000
3. If the nameplate
does not designate
the above
parameters, then:
E=P/(3×I)
In the above
formulas: n
N
is the
rated rotation
speed, P is the
rated power and I
is the rated
current.
Setting range:
010000
P02.24
Initial pole
position of
SM 1
(reserved)
0x00000xFFFF
0
P02.25
Identificatio
n current
of SM 1
(reserved)
0%50.0% (of the motor rated current)
10%