Page #85 background imageLoading...
Page #85 background image
Goodrive30 Series VFD Function parameter list
-79-
Function
code
Name
Description
Default
Modify
12: VFD overload (OL2)
13: Phase loss on input side(SPI)
14: Phase loss on output side (SPO)
15: Rectifier module overheat(OH1)
16: Inverter module overheat (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor autotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback offline fault (PIDE)
23: Braking unit fault (bCE)
24: Running time reached (END)
25: Electronic overload (OL3)
26: Keypad communication error (PCE)
27: Parameter upload error (UPE)
28: Parameter download error (DNE)
2931: Reserved
32: To-ground short-circuit fault 1 (ETH1)
33: To-ground short-circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Mal-adjustment fault (STo)
36: Underload fault (LL)
P07.33
Running
frequency
at present
fault
0.00Hz
P07.34
Ramp
reference
frequency
at
present
fault
0.00Hz
P07.35
Output
voltage at
present
fault
0V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive30 VFD Series and is the answer not in the manual?

INVT Goodrive30 VFD Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive30 VFD Series
CategoryInverter
LanguageEnglish

Related product manuals