EasyManua.ls Logo

ITech IT7900 Series - Surgesag:symmetry Bool

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SURGesag Subsystem
Copyright © ITECH Electronic Co., Ltd. 106
<action>: trigger action setting mode IMMediate|PHASe.
Syntax
SURGesag:ACTion <action>
Argument
IMMediate|PHASe
*RST
IMMediate
Query syntax
SURGesag:ACTion?
Returns
IMMediate|PHASe
Example
SURGesag:ACTion IMMediate //Set the present trigger action to IMMediate.
SURGesag:ACTion IMMediate?
SURGesag:SYMMetry <bool>
This command is used to set and query the symmetry mode switch of the
surge/trap wave.
Syntax
SURGesag:SYMMetry <bool>
Argument
0 | OFF | 1 | ON
*RST
OFF
Query syntax
SURGesag:SYMMetry?
Returns
0 | OFF | 1 | ON
Example
SURGesag:SYMMetry 1 //Turn on symmetry mode.
SURGesag:SYMMetry? //Query the switch status of symmetric mode.

Table of Contents

Other manuals for ITech IT7900 Series

Related product manuals