SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 38
[SOURce:]VOLTage:SLOPe[:AC][:IMMediate]
<NRf+>,[NRf+],[NRf+]
This command is used to set and query the AC voltage slope in normal mode.
<NRf+>: AC voltage slope setting value
Syntax:
VOLTage:SLOPe[:AC][:IMMediate] <NRf+>,[NRf+],[NRf+]
Query syntax:
VOLTage:SLOPe[:AC][:IMMediate]? [MAXimum|MINimum|DEFault]
Example
VOLTage:SLOPe 300.0
VOLT:SLOP 300.0,500,800
VOLT:SLOP?
VOLT:SLOP? MAX
[SOURce:]PVOLtage:SLOPe[:IMMediate][:AC]
<phase>,<NRf+>
Set and query the AC voltage slope of a phase in normal mode.
phase: phase identification.
NRf+: AC voltage slope setting value.
Syntax:
PVOLtage:SLOPe[:IMMediate][:AC] <phase>,<NRf+>
Query syntax:
PVOLtage:SLOPe[:AC][:IMMediate]? <phase>,[MAXimum|MINimum|DEFault]
Example
PVOLT:SLOP C,300.0
PVOLT:SLOP?
PVOLT:SLOP? C,MAX
[SOURce:]VOLTage:SLOPe[:IMMediate]:DC
<NRf+>,[NRf+],[NRf+]
This command is used to set and query the DC voltage slope in normal mode.
<NRf+>: DC voltage slope setting value
Syntax:
[SOURce]VOLTage:SLOPe[:IMMediate]:DC <NRf+>,[NRf+],[NRf+]