EasyManua.ls Logo

ITech IT7900 Series

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 37
Example:
PVOLtage B,300.0
PVOLtage B,MAX
PVOLT? B
PVOLT? B,MAX
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]:D
C <NRf+>,[NRf+],[NRf+]
DC voltage setting command in normal mode.
<NRf+>: DC voltage setting value.
Syntax:
VOLTage[:LEVel][:IMMediate][:AMPLitude]:DC <NRf+>,[NRf+],[NRf+]
Query syntax:
VOLTage[:LEVel][:IMMediate][:AMPLitude]:DC?
*RST:
0V
Example
VOLTage:DC 300.0
VOLTage:DC?
VOLT:DC? MIN
[SOURce:]PVOLtage[:LEVel][:IMMediate][:AMPLitude]:D
C <phase>,<NRf+>
In normal mode, set and query the DC voltage value of a phase.
phase: phase identification.
NRf+: DC voltage setting value.
Syntax:
PVOLtage [:LEVel][:IMMediate][:AMPLitude]:DC <phase>,<NRf+>
Query syntax:
PVOLtage[:LEVel][:IMMediate][:AMPLitude]:DC? <phase>, [MAXimum|
MINimum|DEFault]
Example
PVOLTage:DC C,30.0
PVOLTage:DC? B
PVOLT:DC? B,MIN

Table of Contents

Other manuals for ITech IT7900 Series

Related product manuals