SURGesag Subsystem
Copyright © ITECH Electronic Co., Ltd. 109
Query syntax
SURGesag:VALue:PERCent?
Returns
<NRf+>
Example
SURGesag:VALue:PERCent 10 //Set the drop percentage to 10%
SURGesag:VALue:PERCent? //Query the set drop percentage
SURGesag:VALue <NRf+>
This command is used to set and query the drop value of the trap wave.
<NRf+> drop set value
Syntax
SURGesag:VALue <NRf+>
Argument
<NRf+>
*RST
0
Query syntax
SURGesag:VALue?
Returns
<NRf+>
Example
SURGesag:VALue 20 //Set the drop value to 20V
SURGesag:VALue? //Query the set value of the drop value
SURGesag:VALue? MAX //Query the maximum value of the drop set value.
SURGesag:PHASe:ENABle <A|B|C|AB|AC|BC|ABC>
This command is used to set and query the phase of surge/sag, available only in
three-phase mode.
Syntax
SURGesag:PHASe:ENABle <A|B|C|AB|AC|BC|ABC>
Argument
<A|B|C|AB|AC|BC|ABC>