FETCh & MEASure Commands
Copyright © ITECH Electronic Co., Ltd. 65
Arguments:
[A|B|C|CH1|CH2|CH3]
Returns:
<NRf> …
Example:
FETC:VOLT:DC?
FETCh[:SCALar]:VOLTage:AMPlitude:MAXimum?
MEASure[:SCALar]:VOLTage:AMPlitude:MAXimum?
This command is used to read the peak value of single-phase voltage.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:VOLTage:AMPlitude:MAXimum? [A|B|C|CH1|CH2|CH3]
Arguments:
[A|B|C|CH1|CH2|CH3]
Returns:
<NRf>
Example:
FETC:VOLT:AMP:MAX?
FETCh[:SCALar]:VOLTage:AMPlitude:MAXimum:POSitive?
MEASure[:SCALar]:VOLTage:AMPlitude:MAXimum:POSitive?
This command is used to read the positive peak value of single-phase voltage.
Note: this command parameter is optional. If there is no parameter, it will return
the value of A, B, C three-phase by default.
Syntax:
FETCh[:SCALar]:VOLTage:AMPlitude:MAXimum:POSitive?
[A|B|C|CH1|CH2|CH3]
Arguments:
[A|B|C|CH1|CH2|CH3]