EasyManua.ls Logo

ITech IT7900 Series

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IEEE-488 Common Commands
Copyright © ITECH Electronic Co., Ltd. 139
Chapter20 IEEE-488 Common Commands
IEEE-488 Common commands usually control all instrument functions, such as
reset, status, and synchronization. All common commands consist of a
three-letter mnemonic, and are preceded by an asterisk, E.g:*RST *IDN? *SRE 8.
*CLS
This command clears the error queue and the bits of the following registers:
Standard Event Register
Questionable Event Register
Status byte register
Syntax:
*CLS
Arguments:
None
*ESE
This command sets the bits in the Event Status Enable Register (ESER). The ESER
is an eight-bit register that determines which bits in the Standard Event Status
Register (SESR) will set the Event Summary Bit (ESB) in the Status Byte Register
(SBR).
Syntax
*ESE <NR1>
Arguments
0255
Default value
0
Example
*ESE 128
Query syntax
*ESE?
Returns
<NR1>
Related syntax
*ESR? *PSC *STB?
Bit definition of standard event enable register:

Table of Contents

Other manuals for ITech IT7900 Series

Related product manuals