ISLand Subsystem
Copyright © ITECH Electronic Co., Ltd. 137
Syntax
ISLand:CURRent:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
Arguments
<NRf+>
Query syntax
ISLand:CURRent:CONTrol:LEVel? [A|B|C|CH1|CH2|CH3]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:CURRent:CONTrol:LEVel 1
ISLand:CURRent:CONTrol:LEVel?
ISLand:POWer:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
This command is used to set the function of detecting the input power status
during island simulation.
Syntax
ISLand:POWer:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
Arguments
0|OFF|1|ON
Query syntax
ISLand:POWer:CONTrol[:STATe]? [CH1|CH2|CH3]
Returns
0|1
Example
ISLand:POWer:CONTrol 0,CH2
ISLand:CURRent:CONTrol?
ISLand:POWer:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
This command is usedt to set the power threshold to detect the input power
during island simulation.
Syntax
ISLand:POWer:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]