SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 29
Returns:
NORMal|LIST|SWEep
*RST:
NORMal
Example
FUNC:MODE LIST
[SOURce:]CURRent:PROTection:RMS <NRf+> [,CH1|CH2|CH3]
Set the RMS current protection value of the power supply.
Note: the second parameter [,CH1|CH2|CH3] is optional and only valid in
multi-channel mode.
Syntax:
CURRent:PROTection:RMS <NRf+> [,CH1|CH2|CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
CURRent:PROTection:RMS? [CH1|CH2|CH3],[MAXimum|MINimum|DEFault]
Returns:
MAXimum|MINimum|DEFault
Example
CURR:PROT:RMS 30 //Set the RMS protection level to 30A
CURR:PROT:RMS 10,1 // Set the CH1 RMS protection level to 30A under
multi-channel mode
CURR:PROT:RMS? //Query the RMS protection level
CURR:PROT:RMS? 1 //Query the CH1 RMS protection level
[SOURce:]CURRent:PROTection:DELay <NRf+> [,CH1|CH2|CH3]
Set the RMS current protection delay time, the unit is: s
Syntax:
CURRent:PROTection:DELay <NRf+> [,CH1|CH2|CH3]
Arguments:
MAXimum|MINimum|DEFault
Query syntax:
CURRent:PROTection:DELay? [CH1|CH2|CH3],[MAXimum|MINimum|DEFault]