FETCh & MEASure Commands
Copyright © ITECH Electronic Co., Ltd. 68
FETCh[:SCALar]:POWer:REACtive:TOTal?
MEASure[:SCALar]:POWer:REACtive:TOTal?
This command is used to read the total reactive power value.
Syntax:
FETCh[:SCALar]:POWer:REACtive?
Arguments:
None
Returns:
<NRf>
Example:
FETC:POW:REAC:TOT?
FETCh[:SCALar]:LTLVoltage[:AC]?
MEASure[:SCALar]:LTLVoltage[:AC]?
This command is used to read the line voltage value between B and A, or
between C and A, or between C and B.
Syntax:
FETCh[:SCALar]:LTLVoltage? <BA|CA|CB>
Arguments:
<BA|CA|CB>
Returns:
<NRf>
Example:
FETC:LTLV? CB
FETCh[:SCALar]:VOLTage:HARMonic[:AMPLitude]?
<[A|B|C|CH1|CH2|CH3]>,<NR1>
MEASure[:SCALar]:VOLTage:HARMonic[:AMPLitude]?
<[A|B|C|CH1|CH2|CH3]>,<NR1>