Output Commands
Copyright © ITECH Electronic Co., Ltd. 51
OUTPut:OFF:MODE <CPD>
This command is used to set the output mode when the power output is OFF.
OPENz: disconnect the output relay and the output terminal is in a
high-impedance state.
HIGHz: the output relay is closed and the output terminal is in a high-impedance
state.
SHORt: the output terminal L and N are shorted.
Syntax:
OUTPut:OFF:MODE <CPD>
Arguments:
OPENz|HIGHz|SHORt
Example
OUTP:OFF:MODE SHORt //Set the output terminals L and N to be shorted
when the machine is OFF.
OUTPut:ON:PHASe:MODE <CPD>
This command is used to set and query the phase control mode when the power
output is turned on:
PHASe: when the power is turned on, the output starts at the set phase angle
IMMediate: the output starts at phase 0 when the machine is ON
Syntax:
OUTPut:ON:PHASe:MODE <CPD>
Argument:
PHASe|IMMediate
Query syntax:
OUTPut:ON:PHASe:MODE?
Returns:
PHASe|IMMediate
Example
OUTP:ON:PHAS:MODE IMM
OUTPut:ON:PHASe:LEVel <NRf+>
This command is used to set and query the starting phase angle when the power
output is turned on.