ARB Subsystem
Copyright © ITECH Electronic Co., Ltd. 84
Chapter12 ARB Subsystem
[ARB:]LIST:STATe?
This command is used to query the running status of the list: IDLE: stop, WTG:
waiting for trigger, ACTive: running.
Syntax
[ARB:]LIST:STATe?
Example
LIST:STAT?
[ARB:]LIST:REPeat <NR1>
This command is used to set and query the number of cycles that the list runs.
Syntax
[ARB:]LIST:REPeat <NR1>
Argument:
<NR1>|MINimum|MAXimum|DEFault
*RST
0
Query syntax
[ARB:]LIST:REPeat?
Returns
<NR1>
Example
LIST:REP 10
[ARB:]LIST:TERMinate <CPD>
This command is used to set and query the way to end the list operation. There
are three ways to end:
NORMal: after the list runs, it will automatically return to normal.
LAST: keep the output of the last step after the list runs.
OFF: turn off the output after the list operation is over and still in the list mode.
Syntax
[ARB:]LIST:TERMinate <CPD>