SOURce Commands
Copyright © ITECH Electronic Co., Ltd. 28
Chapter4 SOURce Commands
[SOURce:]FUNCtion <CPD1>[,CPD2]
This command is used to set and query the working mode of the power supply.
Syntax:
FUNCtion <CPD1>[,CPD2]
Arguments:
CPD1:DC|AC|DCAC|ACDC
CPD2:CH1|CH2|CH3
CPD1:No DC or DCAC under three-phase
CPD2: Select a channel, this parameter needs to be input only in multi-channel
mode
Query syntax:
FUNCtion? [CH1|CH2|CH3]
Returns:
<CPD1>:DC|AC|DCAC|ACDC
<CPD2>:CH1|CH2|CH3
*RST:
AC
Example
FUNC AC //Set the instrument work mode to AC mode
FUNC AC,CH1 //Set the CH1 to AC mode in multi-channel mode.
FUNC? CH1 //Query the channel 1 work mode
[SOURce:]FUNCtion:MODE <CPD>
This command is used to set and query the functional mode of the power supply.
Syntax:
FUNCtion:MODE <mode>
Arguments:
NORMal|LIST|SWEep
Query syntax:
FUNCtion:MODE?