ISLand Subsystem
Copyright © ITECH Electronic Co., Ltd. 134
Query syntax
ISLand:QL:LEVel? [A|B|C]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:QL:LEVel 90
ISLand:QL:LEVel?
ISLand:QC:LEVel <NRf+>[,A|B|C]
This command is used to set the reactive power of the capacitive load for island
simulation.
Syntax
ISLand:QC:LEVel <NRf+>[,A|B|C]
Arguments
<NRf+>
Query syntax
ISLand:QC:LEVel? [A|B|C]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:QC:LEVel 90
ISLand:QC:LEVel?
ISLand:MODE <CPD>[,CH1|CH2|CH3]
This command is used to set the island simulation mode.
Syntax
ISLand:MODE <CPD>[,CH1|CH2|CH3]
Arguments
<RLC|P-Q>
Query syntax
ISLand:MODE? [CH1|CH2|CH3]
Returns
<RLC|P-Q>