ISLand Subsystem
Copyright © ITECH Electronic Co., Ltd. 136
ISLand:VOLTage:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
This command is used to set the input voltage and set the voltage threshold when
setting the island simulation.
Syntax
ISLand:VOLTage:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
Arguments
<NRf+>
Query syntax
ISLand:VOLTage:CONTrol:LEVel? [A|B|C|CH1|CH2|CH3]
Returns
MINimum|MAXimum|DEFault
Example
ISLand:VOLTage:CONTrol:LEVel 200
ISLand:VOLTage:CONTrol:LEVel?
ISLand:CURRent:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
This command is used to set the function of detecting input current status during
island simulation.
Syntax
ISLand:CURRent:CONTrol[:STATe] <CPD>[,CH1|CH2|CH3]
Arguments
0|OFF|1|ON
Query syntax
ISLand:CURRent:CONTrol[:STATe]? [CH1|CH2|CH3]
Returns
0|1
Example
ISLand:CURRent:CONTrol 0,CH2
ISLand:CURRent:CONTrol?
ISLand:CURRent:CONTrol:LEVel <NRf+>[,A|B|C|CH1|CH2|CH3]
This command is usedt to set the current threshold to detect the input current
during island simulation.

Table of Contents

Other manuals for ITech IT7900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7900 Series and is the answer not in the manual?

ITech IT7900 Series Specifications

General IconGeneral
BrandITech
ModelIT7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals