WAVE:EDIT:THD:FORM?
WAVEform:EDIT:THD:DATA <order>,<string>
This command is used to set and query the THD value and phase parameter of a
certain order of harmonics
Syntax
WAVEform:EDIT:THD:DATA <order>,<string>
Arguments
<2-50>,<"thd,phase">
Query syntax
WAVEform:EDIT:THD:DATA? <order>
Returns
<string>
Example
WAVE:EDIT:THD:DATA 2, "9.8,0.0"
WAVE:EDIT:THD:DATA? 2
WAVEform:EDIT:THD:SAVE:LOCal <filename>
This command is used to save the presently edited THD wave data to a local file,
and specify the file name (if the file name is the same, it is regarded as modifying
the present waveform, if the file name does not exist, it is regarded as creating a
new file)
Syntax
WAVEform:EDIT:THD:SAVE:LOCal <filename>
Arguments
"filename"
Example
WAVE:EDIT:THD:SAVE:LOC "THD01.csv"
WAVEform:EDIT:THD:SAVE:UDISk <filename>
This command is used to save the presently edited THD wave data to a U disk file,
and specify the file name (if the file name is the same, it is regarded as modifying
the current waveform, if the file name does not exist, it is regarded as creating a
new file)
Syntax
WAVEform:EDIT:THD:SAVE:UDISk <filename>