EasyManuals Logo

ITech IT7900 Series Programming Guide

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
STATus Commands
Copyright © ITECH Electronic Co., Ltd. 122
Returns
<NR1>
STATus:OPERation:PTRansition
Sets the value of the PTR (Positive-Transition) registers. These registers serve as
a polarity filter between the Operation Condition and Operation Event registers.
When a bit in the PTR register is set to 1, then a 0-to-1 transition of the
corresponding bit in the Operation Condition register causes that bit in the
Operation Event register to be set. STATus:PRESet sets all bits in the PTR
registers and clears all bits in the NTR registers.
Syntax
STATus:OPERation:PTRansition <NR1>
Arguments
0-0x7fffffff
Default value
0
Example
STATus:OPERation:PTRansition 128
Query syntax
STATus:OPERation:PTRansition?
Returns
<NR1>
STATus:PRESet
This command is used to preset the value of the status register.
Syntax
STATus:PRESet
Example
STAT: PRES