EasyManua.ls Logo

ITech IT7900 Series

ITech IT7900 Series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FETCh & MEASure Commands
Copyright © ITECH Electronic Co., Ltd. 72
Syntax:
FETCh[:SCALar]:VOLTage:HARMonic:THD? <[A|B|C|CH1|CH2|CH3]>
Arguments:
<[A|B|C|CH1|CH2|CH3]>
Returns:
<NRf>
Example:
FETC: VOLT:HARM:THD? C
FETCh[:SCALar]:CURRent:HARMonic:THD?
<[A|B|C|CH1|CH2|CH3]>
MEASure[:SCALar]:CURRent:HARMonic:THD?
<[A|B|C|CH1|CH2|CH3]>
This command is used to measure the total harmonic distortion of the current.
Syntax:
FETCh[:SCALar]:CURRent:HARMonic:THD? <[A|B|C|CH1|CH2|CH3]>
Arguments:
<[A|B|C|CH1|CH2|CH3]>
Returns:
<NRf>
Example:
FETC: CURR:HARM:THD? A
FETCh[:SCALar]:ARRay:VOLTage:HARMonic[:AMPLitu
de]? <[A|B|C|CH1|CH2|CH3]>,<NR1>
MEASure[:SCALar]:ARRay:VOLTage:HARMonic[:AMPLi
tude]? <[A|B|C|CH1|CH2|CH3]>,<NR1>
This command is used to measure each harmonic amplitude of the voltage.
Meaning: the value range of NR1 is 0-50, the 0th order represents the DC
component, the 1st order represents the fundamental wave, and the 2nd to 50th
order the harmonic components. In this command, if NR1 is assigned a value of
10, the result will list the harmonic amplitude of the voltage from 0 to 10th.

Table of Contents

Other manuals for ITech IT7900 Series

Related product manuals