Routine Maintenance
Checking for Damage
121 121
9811-3400-4
Do not use the machine if a hose or hose fitting is
damaged. Replace damaged hoses before you use the
machine again.
Replacement hoses must be of the same size and
standard.
Checking the ROPS/FOPS Structure
!MWARNING
You could be killed or seriously injured if you operate
a machine with a damaged or missing ROPS/FOPS. If
the Roll Over Protection Structure (ROPS)/Falling
Objects Protection Structure (FOPS) has been in an
accident, do not use the machine until the structure
has been renewed. Modifications and repairs that are
not approved by the manufacturer may be dangerous
and will invalidate the ROPS/FOPS certification.
INT-2-1-9_6
For assistance, contact your JCB distributor. Failure to
take these precautions could result in death or injury to the
operator.
1 Check the structure for damage.
2 Make sure that all the ROPS/FOPS mounting bolts A
are in place and are undamaged.
3 Make sure that the ROPS/FOPS mounting bolts A are
tightened to the correct torque setting.
801230
Fig 66.
Table 23. Torque Setting
Bolts Nm lbf ft
A 330 243