Table 45: EX Series Switch Environmental Tolerances
(Connued)
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX4600
No performance
degradaon to
6,562 feet
(2000 meters)
Normal operaon
ensured in the relave
humidity range 5%
through 90%,
noncondensing
• Short-term
operaon ensured in
the relave humidity
range 5% through
93%, noncondensing
NOTE: As dened in
NEBS GR-63-CORE,
Issue 4, short-term
events can be up to
96 hours in duraon
but not more than
15 days per year.
• Normal operaon
ensured in the
temperature range 32°
F (0° C) through 113°
F (45° C)
• Nonoperang storage
temperature in
shipping container: –
40° F (–40° C)
through 158° F
(70° C)
Complies with
Zone 4
earthquake
requirements per
NEBS GR-63-
CORE, Issue 4.
EX4650 No performance
degradaon to
6,000 feet
(1829 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(condensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX6210 No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
124

Table of Contents

Other manuals for Juniper EX9214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX9214 and is the answer not in the manual?

Juniper EX9214 Specifications

General IconGeneral
BrandJuniper
ModelEX9214
CategorySwitch
LanguageEnglish

Related product manuals