Table 45: EX Series Switch Environmental Tolerances
(Connued)
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX8208
No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX8216 No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX9204 No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 5%
through 90%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Nonoperang storage
temperature in shipping
container: – 40° F (–
40° C) to 158° F (70° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63.
EX9208 No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 5%
through 90%
(noncondensing)
Normal operaon is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Nonoperang storage
temperature in shipping
container: – 40° F (–
40° C) to 158° F (70° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63.
125