Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Feature usage requires a license
or the license for the feature
usage has expired.
Minor
(yellow)
Install the required license for the feature
specied in the alarm. For more
informaon, see Understanding Soware
Licenses for EX Series Switches.
Temperature The chassis temperature has
exceeded 131° F (55° C), the
fans have been turned on to
full speed, and one or more
fans have failed.
Minor
(yellow)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Replace the fan tray.
The chassis temperature has
exceeded 149° F (65° C), and
the fans have been turned on
to full speed.
Minor
(yellow)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Check the fans.
The chassis temperature has
exceeded 149° F (65° C), and a
fan has failed. If this condion
persists for more than
four minutes, the switch shuts
down.
Major (red)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Check the fan.
298

Table of Contents

Other manuals for Juniper EX9214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX9214 and is the answer not in the manual?

Juniper EX9214 Specifications

General IconGeneral
BrandJuniper
ModelEX9214
CategorySwitch
LanguageEnglish

Related product manuals