Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Feature usage requires a license
or the license for the feature
usage has expired.
Minor
(yellow)
Install the required license for the feature
specied in the alarm. For more
informaon, see Understanding Soware
Licenses for EX Series Switches.
Temperature The chassis temperature has
exceeded 131° F (55° C), the
fans have been turned on to
full speed, and one or more
fans have failed.
Minor
(yellow)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Replace the fan tray.
The chassis temperature has
exceeded 149° F (65° C), and
the fans have been turned on
to full speed.
Minor
(yellow)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Check the fans.
The chassis temperature has
exceeded 149° F (65° C), and a
fan has failed. If this condion
persists for more than
four minutes, the switch shuts
down.
Major (red)
• Check room temperature.
• Check air lter and replace it, if
required.
• Check airow.
• Check the fan.
298