When the services gateway is powered on for the first time, the system looks for a
DHCP server. If it does not find one, the system assigns an IP address within the
192.168.1.0/24 subnetwork to any devices connected to the system.
To connect to the J-Web interface through port fe–0/0/0 on the services gateway,
see Figure 13 on page 61.
Figure 13: Connecting to the Ethernet Port on an SRX100 Services Gateway
1. From the management device you use to access the J-Web interface (such as a
PC or a laptop), verify that the address of the port you connect to is set to one
of the following values:
■
Ethernet address on the 192.168.1/24 subnetwork other than 192.168.1.1
■ Ethernet address from a DHCP server
2. Plug one end of the Ethernet cable into the Ethernet port on the management
device.
3. Connect the other end of the Ethernet cable to the built-in Fast Ethernet port on
the services gateway.
4.
Wait until the Status LED on the front panel turns solid green.
5. Turn on the power to the management device. The services gateway assigns an
IP address to the management device within the 192.168.1.0/24 subnetwork
if the services gateway is configured to use DHCP.
6. From the management device, open a Web browser and enter the IP address
192.168.1.1 in the address field. The J-Web Quick Configuration Set Up page
appears.
7. Configure basic settings for your services gateway.
Connecting an SRX100 Services Gateway to the J-Web Interface ■ 61
Chapter 12: Establishing Basic Connectivity for the SRX100 Services Gateway