Chapter 13
Maintaining the SRX100 Services
Gateway Hardware Components
This chapter describes how to maintain the hardware components of the SRX100
Services Gateway. This chapter includes the following section:
Maintaining the SRX100 Services Gateway Hardware Components on page 77
Maintaining the SRX100 Services Gateway Hardware Components
Table 27 on page 77 describes the common tasks for maintaining the hardware
components of the services gateway.
Table 27: Maintenance Procedures for the SRX100 Services Gateway Hardware Components
DescriptionMaintenance Procedures
For optimum performance of the services gateway, you should regularly perform the following
preventive maintenance procedures :
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the device and into the air intake vents.
Routine maintenance
To maintain the power supply on the services gateway:
Make sure that the power and grounding cables are arranged so that they do not obstruct
access to other device components.
Periodically inspect the site to ensure that the grounding and power cables connected to
the device are securely in place and that there is no moisture accumulating near the device.
CAUTION: We recommend using a surge protector for the power connection.
Maintaining the power
supply
Related Topics Site Preparation Checklist for the SRX100 Services Gateway on page 17
Monitoring the SRX100 Services Gateway Chassis Using the CLI on page 79
Monitoring the SRX100 Services Gateway Components Using LEDs on page 81
Monitoring the SRX100 Services Gateway Using Chassis Alarm Conditions on
page 83
Monitoring the SRX100 Services Gateway Power System on page 84
Maintaining the SRX100 Services Gateway Hardware Components 77

Table of Contents

Other manuals for Juniper SRX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX100 and is the answer not in the manual?

Juniper SRX100 Specifications

General IconGeneral
Routing protocolsBGP, IS-IS, MPLS, OSPF
Switching protocolsVLAN 802.1Q, 802.3ad/LACP, STP
Supported network protocolsIPv4, IPv6, CLNS
Firewall securityYes
Security algorithms3DES, DES
Authentication methodRADIUS, RSA SecureID, LDAP
VPN supportIPsec VPN
Data transfer rate0.1 Gbit/s
Input voltage100 - 240 V
Input frequency50/60 Hz
Heat dissipation35 BTU/h
Power requirements100-240, 50/60
Power over Ethernet (PoE)No
Power consumption (typical)30 W
SafetyUL 60950-1, CSA 60950-1, AS / NZS 60950-1, AS / NZS 60950-1, CB Scheme, EN 60950-1
CertificationFCC Class B ICES class B AS / NZS CISPR22 Class B AS / NZS CISPR22 Class B VCCI Class B EN 55022 Class B, EN 300386
Mounting typeRack mounting
Internal memory1024 MB
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight1100 g
Dimensions (WxDxH)216 x 147 x 36 mm