EasyManua.ls Logo

KCP 113 - Electric Problems; When Main Panel Is Not Powered

Default Icon
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KCP Heavy Industries Co., Ltd. Troubleshooting
6-9
6.2.2 Electric problems
6.2.2.1 When main panel is not powered
Notice ___________________________________________________________________________
If main panel is not powered, the machine cannot be operating.
However, some of function can be operated by manual override. ________________________
Possible
cause
Check point
Diagnosis
Solution
Maintenance
level
Maintenance level : A(KCP service center repair), B(KCP engineer dispatch or phone call)
Main panel
wiring
disconnected
Main relay
Check P1
main power
Replace main
relay(CRA)
B
F2 Fuse
Check if main relay
is function normally.
Check if F2 is
disconnected
Replace F2 fuse.
B

Table of Contents