KCP Heavy Industries Co., Ltd. Maintenance
7-18
7.10 S-tube
► Minimize the R.P.M
► To raise the s-valve vertically, tilt the s-valve manual transition valve.
► As soon as the s-valve comes to the center, press the emergency stop button on the
control panel and turn off the engine.
Note ___________________________________________________________________
The wear parts must be replaced if visual inspection reveals wear or if there is insufficient
pressure build-up in the delivery line.