KCP Heavy Industries Co., Ltd. Troubleshooting
6-14
6.2.4.2 When pumping is not functioning
Notice __________________________________________________________________________
Pumping is not functioning when emergency mode.
________________________________________________________________________________
Possible cause
Check point
Diagnosis
Solution
Maintenance
level
Maintenance level : A(Repair at KCP service workshop), B(KCP engineer dispatch or phone call)
Pumping sol.
failure
Main panel
F9 fuse
Firstly check wiring of
pumping sol.
Check main panel
Fuse F9, if burnt.
B
Pumping
sol v/v
Check main panel
fuse F9.
Try to operate the
machine with
manual override
A/S serviceman
dispatch
B
Sensing ball
v/v closed
Ball v/v
Check if ball v/v is
open.
Open ball v/v if
closed.
B