KCP Heavy Industries Co., Ltd. Troubleshooting
6-17
Possible cause
Check
point
Diagnosis
Solution
Maintenance
level
Maintenance level : A(Repair at KCP service workshop), B(KCP engineer dispatch or phone call)
Acc bladder
failure
(Refer to Page
6-31. Pic#7)
Acc
pressure
gauge
Acc pressure is under
100BAR.
Accumulation is late
during max RPM.
Reduce outvolume.
(check if reduced, and
problems are still
discovered).
Replace the acc
Tank.
B
E.C.O Switch and usage depends on main panel models.
Inside of main panel
Outside of main panel
Turn ECO switch to ON as above pic or toggle s/w to up.
E.C.O can be accumulated pressure of S-v/v switching during emergency situation
because of accumulator pump broken. This switch is only for emergency when accumulator
pump is broken.
When accumulator pump is broken, lots of other metal articles such as pump’s plate or
shoe could be found. So it must be replaced as soon as possible.
Cautions during accumulator pump replacement
Fully drain out all of concrete by reverse pumping, turn OFF the ECO switch, fold the
booms completely and replace the accumulator pump.