Load Edge Series
22 Connections
(3) External control cable
As an external control cable, use a twisted cable when connecting.
The wire lines should be selected according to the following requirement.
The input signal should be DC signal. In case AC signal is inputted, it is necessary to
offset voltage to keep the voltage above 0V any time.
Input voltage range is 0 to 10 Voltage DC to 300 kHz (3dB)
Suggested wire line
Single wire line
Diameter: 0.4mm-1.2mm (AWG26-AWG16)
Twisted wire line
Cross section: 0.3mm
2
-1.25mm
2
(AWG22-AWG16), Diameter 0.18mm or more.
Fig. 2-2-4 Strip gauge of the wire and connecting method
Do NOT apply any Volt other than the range (0-10V). Any voltage outside this