EN UG-020 Link 6 user guide r1.0 272
The initial cause of the fault is still in effect.
After clearing the initial fault, another fault is triggered in the current configuration of the robot.
Remedy
Procedure
Make sure the robot is far from its position limits.
Make sure the robot is outside of the enabled protection zones.
a) Tap Safety > Protection Zones.
b) Visualize the current pose of the robot relative to the protection zones.
c) Move the robot to a safe position using either Hand Guiding or Manual Jog mode.
Related topics
Protection zones on page 69
Recovery mode on page 106
State: Fault on page 98
Issues related to plugins
Examples of issues you may have with plugins deal with plugin installation, configuration, and
activation.
Why can I not configure Industrial I/Os?
Condition
The fields on the Configurations page of the Industrial I/O plugin page are not selectable.
Cause
The Industrial I/Os need to be switched on before they can be configured.
Remedy
Make sure the Industrial I/Os are receiving power.
Related topics
Industrial I/O plugin on page 245
Industrial I/O panel overview on page 32
Issues related to programs and programming
Examples of issues related to programs and programming deal with variables, action blocks, and
programs.
Why can I not assign a variable to a field?
Condition
When a program is being created or modified, the user attempts to assign a variable to a field.