7
-
46
RX6010C / RX6010PC
Make sure to follow the instructions
below to keep the air conditioner in
the best condition:
1. Operation in winter season:
During the winter time, run the air
conditioner once or twice every
month to prevent refrigerant leak-
age and corrosion in the air con-
ditioner system and to facilitate oil
circulation in the compressor in
order to prevent malfunction.
The A/C does not operate when
the air temperature is below 2
.
Therefore, warm the inside air by
operating the heater in order to be
able to operate the A/C.
2. Air conditioner condenser care:
If there is foreign material in the
A/C condenser and engine radia-
tor, their cooling performance may
be deteriorated. Therefore, always
keep them clean for their optimal
cooling performance. When clean-
ing the core of the condenser, use
a soft brush and water. Carefully
AIR CONDITIONER MAINTENANCE (AS)
clean the condenser so as not to
bend it.
3. Operation in summer season:
Make sure to check the tension of
the A/C belt before using the A/C
frequently.
SPECIFICATIONS FOR A/C REFRIG-
ERANT AND LUBRICANT
Item
New
refrigerant
Compressor
oil
Type HFC-134a UCON488
Charging
amount
1.65 lbs.
(0.75 kg)
0.07 U.S.gal
(265cc)
The A/C system is charged with
new refrigerant that does not de-
stroy the ozone layer. Be careful
when servicing the A/C system.
Do not use unspecied refriger-
ant and compressor oil, or the
air conditioner system could be
seriously damaged.
The performance of the A/C
becomes poor when the refrig-
erant is insufficient. However,
charging the air conditioner
with excessive refrigerant also
affects its performance nega-
tively. Therefore, have the sys-
tem checked by a KIOTI Dealer
if malfunction is found.
CAUTION
Have the air conditioner ser-
vic ed by qualified se rvi ce
personnel. If it is serviced by
an unqualied person, he/she
can be injured by the refriger-
ant under high pressure.
WARNING