XII - 1
Maintenance - Electrical System
12.3 Battery Main Switch
There is an interrupter switch (1) for the battery minus
cable at the rear left-hand side of the vehicle in case of
repairs and emergencies.
I - Switch pushed in and locked: battery is connected.
II - Switch pulled out: battery is disconnected.
12.2 Batteries
The self-propelled high performance mower-conditioner is
equipped with two batteries, each 12 V (135 AH), which
are connected parallel.
The battery will drain if the ignition is
set to stage 1 or 2, even if the main
switch is switched off.
12 Maintenance -
Electrical System
12.1 Electrical System
Specifications
Alternator power ---------------------------------------- 14V /150 A
Number of batteries
--------------------------------------------- 2
Battery voltage ----------------------------------------------------- 12 V
Battery capacity ----------------------------------------- (2x) 135 AH
1
BMII-210
I
II
2
BMII-231
During repair work (welding) always
switch off engine , set main battery
switch (1) to pos. II and remove the
cable plug from the unit pump (PLD)
control unit at the engine!