XII - 14
Maintenance - Electrical System
12.12.1 Fehlercodes SmartDrive
No. Picture Remark Relief
Limp-Mod
e
01 Over-voltage error - Check alternator charging circuit
02 Under-voltage error -Recharge battery
- Check wiring
03 12V supply Replace
calculator!
12V supply voltage error - Replace Smart Drive
04 5V supply Replace
calculator!
5V supply voltage error - Replace Smart Drive
16 CS ParameterError! CS parameter error
17 Limit Parameter
Error!
Limit min max parameter error
18 E2PROMError! E2PROM error
19 Digital Pot Error! Digital Pot error
20 EV DAC Error! EV DAC error
21 I2C Bus Error! I2C Bus error
30 Error on control loop
pump 1!
Pump 1 control loop error X
31 Error on control loop
pump 2!
Pump 2 control loop error X
32 Feedback error
pump 1!
Pump 1 pivoting angle sensor
error: Signal out of range
- Check wiring
- Check signal - Replace or
adjust pivoting angle sensor
X
33 Feedback error
pump 2!
Pump 2 pivoting angle sensor
error: Signal out of range
- Check wiring
- Check signal - Replace or
adjust pivoting angle sensor
X
34 Neutral drift too high
pump 1!
Pump 1 pivoting angle sensor
error: Neutral out of range
X
35 Neutral drift too high
pump 2!
Pump 2 pivoting angle sensor
error: Neutral out of range
X