Chapter 3 Install the Slim Profile InTouch
62
Step 1: Prepare the location
Determine the power source for your site
Before you start the installation, plan how the InTouch will connect to a power
source at your site.
Power options
Install using a Power-over-Ethernet (PoE) or PoE Plus cable for power.
Install near an AC outlet and use the wall transformer connection for power.
Important notes
Select a location where the distance from the power cable hole at the bottom
of the InTouch is not more than 5 feet (1.5 meters) from the AC outlet. Install
an outlet if necessary.
The AC line that supplies power to the InTouch must be equipped with an
appropriate disconnect device (20A maximum circuit breaker).
Do not connect the InTouch power line to circuits that are being used for
electrical devices that draw large amounts of power, such as air conditioning
units, electrical motors, and compressors.
Avoid running communications cable near devices that interfere with data
transmission.