COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S81
9Y3200007CRS0119US0
Name Injector charge voltage: High
ISO 14229
P-Code
P0200
J1939-73
SPN 523535
FMI 0
SPN Name
SAE J1939 Table C1
proprietary
DTC Name Injector charge voltage: High
Detection item Injector charge voltage: High
DTC Set
Preconditions
Battery voltage is normal
CPU is normal
DTC set parameter Injector charge voltage: High
Time to action or
number of error
detection
10 sec. or more
Limp Home Action
by engine ECU
(system action)
Output limitation: Approximately 75 % of normal condition
•EGR stop
Intake throttle 100 % open
Engine forcibly stopped 60 sec. later
Behaviour During
Malfunction
Insufficient output
Worsening exhaust gas performance
Engine stops
Engine Warning
Light
•ON
Recovery from
error
Key switch turn OFF
Delay time for
recovery
Remark