EasyManua.ls Logo

Kubota 07-CR-E5 - Air Intake System Inspection Procedure; Inspection Procedure for each System

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S320
6. INSPECTION PROCEDURE FOR EACH SYSTEM
[1] AIR INTAKE SYSTEM INSPECTION PROCEDURE
1. Check the Air Cleaner
1. Check the air cleaner for clogging.
Clean air cleaner element (Primary and Secondary) every 250
hours.
Replace air cleaner element:
Once yearly or after every sixth cleaning, whichever comes first.
9Y3200007CRS0515US0
2. Check the Suction Path
1. Check the suction path for leaks. (including EGR valve,
turbocharger, intercooler, etc.)
Suction path joints.
Suction pipes, hoses.
NOTE
A small amount of gas and water bleeds from the valve
chamber gas bleeding hole of the EGR valve. This is
normal.
9Y3200007CRS0516US0
OK Go to "2. Check the Suction Path".
NG Clean or replace.
OK Normal.
NG Repair or replace the malfunctioning component.
(1) Hose Clamp
(2) Hose
(3) Turbocharger
(4) EGR Valve
KiSC issued 03, 2022 A