COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S227
(32) Sensor Supply Voltage 1 Abnormality (DTC P0642 / 3509-4, P0643 /
3509-3)
P0642 / 3509-4: Sensor supply voltage 1: Low
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Engine stops in some case
Detection item:
Sensor supply voltage 1 error or recognition error
DTC set preconditions:
Battery voltage is normal
Key switch turn ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Voltage to sensor is below 4.375 V
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 50 % of normal condition
Speed limitation (Accelerator limitation: 50 %)
EGR stop
Intake throttle 100 % open
Recovery from error:
Key switch turn OFF
9Y3200007CRS0344US0
P0643 / 3509-3: Sensor supply voltage 1: High
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Engine stops in some case
Detection item:
Sensor supply voltage 1 error or recognition error
DTC set preconditions:
Battery voltage is normal
Key switch turn ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Voltage to sensor is above 5.625 V
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 50 % of normal condition
Speed limitation (Accelerator limitation: 50 %)
EGR stop
Intake throttle 100 % open
Recovery from error:
Key switch turn OFF